Online

Ready

Water tank

--%

Fuel

--%
EmptyFull
Warns below 15 percent

Battery

--V
10 V14.5 V
Warns below 11.5 V, stops the pump below 11.0 V

Water level, last 24 hours

Alarms

Device

Inputs at the pump

Recent events

    Concept, not built

    Smart start

    How outside information could prepare or start this pump. Every option starts as notify only, and the pump still refuses to run if its own checks fail: water, E-stop, fuel.

    Neighbour pumps (example)

    2 pumps running within 5 km
    Area names only. No owner names or exact locations.
    Notify
    Tell nearby members when my pump starts
    Notify me when 2 or more pumps within 5 km are running

    Information sources

    Emergency WA incidents and warnings
    Access to be confirmed with DFES.
    Planned
    Satellite hotspots (Himawari, VIIRS)
    Reports can be 17 minutes to 3 hours old. Early hint only.
    Planned
    Fire danger and Total Fire Ban
    Reminds you to check fuel and water on bad days.
    Planned
    Neighbouring pumps on Pumpwarden
    Opt-in. Count of pumps running within your radius.
    Planned

    This pump

    Location

    Pin
    Not set

    The controller has no GPS, so this is the pin you set. It stays with the pump if you replace the controller. Owners and operators see the exact spot; viewers see an area of about 2 km.

    Starting

    Fuel

    Fuel sender fitted
    Turn off if this tank has no resistive fuel sender. The fuel level switch still works.

    Battery and clock

    Water tank

    Water level sensor fitted (4-20 mA)
    Turn off if this tank has no level transmitter. The water level switch still protects the pump.

    Each value is sent to the pump as one setting. The pump checks the range and refuses a bad value, then keeps it in its own memory.

    People with access

    Concept, to be worked out

    Fire brigade access

    Needs agreement with the brigade and your insurer. Shows how you stay in control of it.

    Wandering Volunteer Bush Fire Brigade
    Can see status, water, fuel and readiness
    View
    Allow brigade to stop my pump
    Logged, and you are told every time
    Allow brigade to start my pump
    Only while an official warning covers this address
    Access ends
    End of fire season, or when you remove it
    31 Mar
    Concept, not built

    Your plan

    Pumpwarden Ready
    One pump, remote start and stop, push and email alerts, history, up to 5 people
    Active
    Renews 1 September
    A$149 a year, paid once before the season. The first year came with your controller.

    If a plan lapses, the pump keeps working from its own buttons and inputs. Only the remote features switch off.

    Concept, not built

    Notifications on this phone

    Push notifications
    Not enabled
    Pump starts or stops
    Faults and failed starts
    Water or fuel low
    Pump offline for more than 15 minutes

    On iPhone, notifications only work after Add to Home Screen. They can be silenced by Do Not Disturb, so treat them as a heads-up. Email and Home Assistant alerts can run alongside.